- Products
- Resources
- Support
- About Us
- Blog
- Contact
- Online Store
SUPPORT / ARTICLES
Flavor chemistry demands sample preparation techniques that can isolate delicate volatile aroma compounds without thermal degradation or artifact formation. Solvent-Assisted Flavor Evaporation (SAFE) has emerged as the gold standard method for extracting volatile analytes from complex food matrices, particularly when analyzing odor and aroma compounds. Since its introduction in 1999, SAFE has become essential for laboratories conducting gas chromatography-mass spectrometry (GC-MS) and gas chromatography-olfactometry (GC-O) analyses.
What sets SAFE apart is its ability to separate volatile compounds from non-volatile interferences like lipids, triglycerides, and pigments under mild conditions—high vacuum and low temperatures (40-50°C)—thereby preventing the degradation of thermally labile odorants. However, the SAFE process doesn't end with distillation. Nearly all research applications using SAFE rely on nitrogen evaporation as a critical final concentration step to prepare samples for instrumental analysis.
Table of Contents:
What is SAFE and How Does It Work?
The Critical Role of Nitrogen Evaporation in SAFE Workflows
Why Nitrogen Evaporation Excels for SAFE Applications
Real-World Applications: SAFE and Nitrogen Evaporation in Flavor Analysis
Optimizing Nitrogen Evaporation for SAFE Extracts
SAFE vs. Alternative Extraction Methods
Emerging Developments: Automated SAFE
Instrumentation Considerations
Integration with Analytical Workflows
Conclusion: A Proven Partnership for Flavor Chemistry
SAFE is a high-vacuum distillation technique specifically designed for flavor and aroma analysis in food science. The method addresses a fundamental challenge in flavor chemistry: how to isolate volatile aroma compounds from complex matrices containing high concentrations of non-volatile substances that would otherwise contaminate analytical instruments or interfere with chromatographic separations.
The typical SAFE workflow involves several coordinated steps:
Sample Extraction: Food samples are first extracted with organic solvents. Common extraction solvents include dichloromethane, diethyl ether, pentane, or methanol, depending on the target compounds and matrix. For example, when analyzing beef fat volatiles, researchers found that dichloromethane and pentane extraction yielded the highest number of odor-active compounds.
SAFE Distillation: The solvent extract is loaded into the SAFE apparatus, which consists of a dropping funnel, thermostated evaporation flask, and recondensation flask connected under high vacuum (typically 10⁻⁴ torr). Small portions of the extract are introduced dropwise into the heated evaporation flask. Volatile compounds quickly evaporate while non-volatile materials—including triglycerides, waxes, pigments (chlorophylls and carotenoids), and other matrix components—remain in the evaporation flask.
Collection: The volatile fraction condenses in a collection flask cooled with liquid nitrogen, resulting in a colorless, transparent extract free from non-volatile contamination.
Concentration: The collected volatile fraction must be further concentrated before analysis. This is where nitrogen evaporation becomes indispensable.
After SAFE distillation, the volatile extract typically exists in a relatively large volume of organic solvent that must be concentrated to enable detection and quantification of trace-level aroma compounds. Research literature consistently demonstrates that nitrogen evaporation—often used in conjunction with Vigreux columns or micro-Snyder columns—is the preferred method for this final concentration step.
A comprehensive review of SAFE methodologies reveals a multi-stage concentration approach:
- Stage 1: Vigreux Column Concentration: After SAFE distillation, water is removed from the collected volatile fraction using anhydrous sodium sulfate (Na₂SO₄), a chemical drying agent that absorbs residual moisture. The dried extract is then concentrated using a Vigreux column (typically 50 cm × 1 cm inner diameter) under atmospheric pressure at controlled temperature (approximately 43-48°C). This reduces the volume from several hundred milliliters to approximately 1-3 mL.
- Stage 2: Nitrogen Blowdown: The concentrate undergoes final concentration to 200 μL to 1 mL using nitrogen evaporation with high-purity nitrogen (≥99.999%). This gentle, controlled evaporation ensures that even the most volatile aroma compounds are retained while achieving the concentration levels necessary for sensitive GC-MS and GC-O analysis.
This two-stage approach balances efficiency with sample preservation. The Vigreux column handles bulk solvent removal, while nitrogen blowdown provides precise control during the critical final concentration phase.
Nitrogen blowdown evaporation offers several advantages that make it ideally suited for concentrating SAFE extracts containing volatile aroma compounds:
- Gentle, Controlled Evaporation: Nitrogen evaporation works by applying a steady stream of inert nitrogen gas just above the sample surface, which lowers vapor pressure and continuously removes solvent-saturated air. This prevents volatile compounds from re-equilibrating with the liquid phase, accelerating evaporation without harsh conditions.
- Temperature Control: The combination of nitrogen flow and controlled water bath heating allows precise temperature management. For heat-sensitive volatile compounds, bath temperatures of 30-40°C combat the cooling effect of evaporation while remaining well below solvent boiling points and thermal degradation thresholds. This is critical when working with thermally labile odorants that define food aromas.
- Inert Atmosphere: Using nitrogen—an inert, non-reactive gas—minimizes oxidation and chemical degradation of sensitive aroma compounds. This is particularly important for unsaturated aldehydes, esters, and other reactive volatiles that contribute significantly to food flavor profiles.
- High Throughput: Modern nitrogen evaporators like Organomation's N-EVAP and MULTIVAP systems can concentrate multiple samples simultaneously with individual flow control at each position. This capability dramatically increases laboratory efficiency when processing the numerous samples typical of flavor profiling studies.
- Precision to Dryness or Endpoint: Nitrogen evaporation provides the control needed to concentrate samples to a precise final volume or to complete dryness for reconstitution in a specific solvent. This flexibility is essential when optimizing sample preparation for different analytical methods or when solvent exchange is required.
The combination of SAFE distillation and nitrogen evaporation has been successfully applied across diverse food and beverage matrices:
- Olive Oil Aroma Profiling: Researchers used a modified approach combining liquid-liquid extraction with SAFE, followed by Vigreux column concentration and nitrogen blowdown. This method isolated 41 aroma compounds from just 5 grams of extra virgin olive oil, including critical C5 and C6 aliphatic compounds that serve as markers for ripening degree and quality. The SAFE step removed pigments (chlorophylls and carotenoids) that had created a dark green color in the initial extract, resulting in colorless, transparent extracts suitable for GC-MS analysis.
- Beef Fat Flavor Chemistry: Analysis of dry-rendered beef fat using SAFE with four different extraction solvents, followed by concentration and GC-MS/GC-O analysis, identified 96 volatile compounds and 73 odor-active compounds. Nitrogen evaporation was essential for achieving the final concentration needed to detect and quantify key aroma compounds with odor activity values (OAVs) ≥1, including compounds responsible for meaty, roasted, and fatty aroma notes.
- Tea Aroma Analysis: A comprehensive study of tea volatile components used SAFE distillation followed by extract concentration and GC-MS analysis. The protocol specifically included "extract concentration" as a critical step between SAFE distillation and analysis, enabling detection of tea's complex, low-concentration aroma profile.
- Fish Soup Volatile Analysis: Researchers extracted fish soup with diethyl ether/pentane mixture, performed SAFE distillation for 2 hours at 10⁻⁴ torr, collected the fraction in liquid nitrogen, removed water with anhydrous Na₂SO₄, concentrated to 10 mL through a Vigreux column, then further reduced the volume by nitrogen stream purging before GC-O-MS analysis. This workflow exemplifies the standard multi-stage concentration approach employed in flavor chemistry.
To achieve optimal results when concentrating SAFE extracts, consider these best practices based on Organomation's expertise and published research:
- Select Appropriate Flow Rates: Optimal nitrogen flow creates a visible dimple on the sample surface without causing splashing. Smaller sample tubes (e.g., microcentrifuge tubes) work efficiently with 19-gauge needles, while larger tubes benefit from wider needles that accommodate higher flow rates.
- Control Temperature Carefully: Set the water bath temperature 2-3°C below the boiling point of your solvent for efficient evaporation. For heat-sensitive samples or when preserving the most volatile aroma compounds, use lower temperatures (30-40°C) to minimize thermal stress.
- Ensure Dry Gas: Whether using nitrogen cylinders, laboratory nitrogen lines, or a nitrogen generator like Organomation's NITRO-GEN+, ensure the gas is dry. Moisture in the gas stream significantly reduces evaporation efficiency.
- Monitor Evaporation Progress: When concentrating to a specific volume rather than to dryness, monitor the process carefully. For SAFE extracts destined for GC-MS or GC-O analysis, typical final volumes range from 200 μL to 1 mL, depending on the concentration of target analytes and instrument sensitivity requirements.
- Consider Sample Position: Nitrogen evaporators with individual needle height adjustment allow optimization for varying tube sizes and solvent volumes, ensuring consistent results across all sample positions.
While other volatile extraction methods exist—including headspace solid-phase microextraction (HS-SPME), purge-and-trap, and direct solvent extraction—SAFE combined with nitrogen evaporation offers distinct advantages for comprehensive aroma profiling:
- Comprehensive Volatile Recovery: SAFE extracts both low and high-boiling-point compounds more completely than HS-SPME, which favors highly volatile compounds. When researchers compared extraction methods for olive oil, SAFE identified 20 aroma compounds while HS-SPME detected 23, but the combination of liquid-liquid extraction with SAFE (OA-LLE + SAFE) yielded 41 compounds, including semi-volatiles that neither method alone could capture.
- Elimination of Non-Volatile Interference: Unlike direct solvent extraction, SAFE physically removes non-volatile materials that would contaminate GC columns, interfere with mass spectrometry detection, or require extensive cleanup procedures. This results in cleaner chromatograms and extended instrument lifetimes.
- Artifact-Free Extraction: SAFE's low-temperature, high-vacuum operation prevents the formation of thermal artifacts and degradation products that can occur with higher-temperature distillation methods. This is crucial when the goal is to characterize the true aroma profile of a food product rather than compounds formed during extraction.
- Scalability: SAFE can process relatively small sample sizes (5-15 grams) while still achieving excellent sensitivity, making it valuable for analyzing rare or expensive food ingredients.
Recent innovations have addressed some traditional limitations of SAFE through automation. Researchers at the Leibniz Institute for Food Systems Biology developed an automated SAFE (aSAFE) system that replaces the manual valve with an electronically controlled pneumatic valve. This automation provides several benefits:
- Higher Yields: Shorter valve open times (0.2 seconds) and longer closed times (20 seconds) increase recovery of high-boiling odorants and improve performance with lipid-rich samples.
- Reduced Contamination Risk: Automated operation eliminates human error that could allow non-volatile material to transfer into the volatile isolate.
- Consistent Reproducibility: Precise electronic control ensures uniform extract portions and consistent yields across samples.
- Reduced Labor: Automated liquid nitrogen refill and endpoint recognition systems minimize manual intervention.
Even with these advances, nitrogen evaporation remains the essential final step for concentrating a SAFE extracts before analysis.
For laboratories establishing or optimizing SAFE workflows, selecting appropriate nitrogen evaporation equipment is crucial. Organomation offers several systems well-suited for SAFE applications:
- N-EVAP Series: The classic N-EVAP nitrogen evaporators are available in configurations from 6 to 45 positions, providing flexibility for different throughput requirements. Individual flow control at each position allows simultaneous concentration of samples with varying volumes or solvents—ideal for flavor studies comparing multiple extraction conditions.
- MULTIVAP Systems: For higher-throughput laboratories processing 40+ samples per batch, MULTIVAP evaporators offer automated or semi-automated operation with programmable temperature control and needle positioning. These systems are particularly valuable for large-scale flavor profiling projects or quality control applications.
- MICROVAP: For small-volume samples in microcentrifuge tubes or microplates, MICROVAP evaporators provide a compact, efficient solution for life science and pharmaceutical applications that may include volatile compound analysis.
- NITRO-GEN+ Generator: This reliable nitrogen generator produces up to 35 LPM of nitrogen from compressed air, eliminating the need for nitrogen cylinder storage and delivery. It's compatible with all Organomation nitrogen evaporators up to 100 sample positions and offers reduced operating costs and environmental impact.
The value of properly concentrated SAFE extracts becomes evident during subsequent analytical steps:
- GC-MS Analysis: Clean, concentrated extracts produce sharper peaks with improved signal-to-noise ratios, enabling identification of trace-level aroma compounds. The removal of non-volatiles during SAFE prevents column contamination and maintains baseline stability across long analytical sequences.
- GC-Olfactometry (GC-O): For GC-O work, where trained panelists evaluate the odor of compounds as they elute from the GC column, SAFE ensures that non-volatile materials don't interfere with olfactory assessment. Proper concentration via nitrogen evaporation ensures that even low-concentration odorants reach concentrations above human detection thresholds.
- Aroma Extract Dilution Analysis (AEDA): This technique, which determines flavor dilution (FD) factors by testing serial dilutions of extracts, requires precise initial concentrations. Nitrogen evaporation's ability to achieve specific endpoint volumes enables accurate preparation of dilution series.
The combination of SAFE distillation and nitrogen blowdown evaporation represents a mature, reliable approach to flavor chemistry sample preparation. By separating the challenges of non-volatile removal (via SAFE) and precise concentration (via nitrogen evaporation), this workflow achieves what neither technique can accomplish alone: clean, concentrated extracts that faithfully represent the volatile aroma profile of complex food matrices.
For over 65 years, Organomation has supported flavor chemistry research by providing reliable, precise nitrogen evaporation systems. As the demand for authentic flavor analysis continues to grow across food science, quality control, and product development applications, the partnership between SAFE technology and Organomation's nitrogen evaporators will remain central to advancing our understanding of food aroma and flavor.
Whether your laboratory is analyzing olive oils, evaluating meat flavors, profiling tea varieties, or developing new food products, implementing SAFE with optimized nitrogen evaporation workflows can elevate the quality and reliability of your volatile compound analysis. The gentle, controlled concentration that nitrogen evaporation provides is not just a convenience—it's an essential step in preserving the aromatic integrity that defines the foods we love.
About Organomation: For over six decades, Organomation has been the trusted partner for laboratories worldwide seeking reliable sample preparation solutions. Our nitrogen evaporation systems are used in environmental testing, pharmaceutical development, food safety, and flavor chemistry applications. From compact benchtop units to high-throughput automated systems, Organomation provides the tools researchers need to concentrate samples efficiently while maintaining integrity.
If you need support from one of our technicians, please fill out our Contact Help Support form and we will respond as quickly as possible! For all other enquiries, please use this general contact form.
USA 888.838.7300
Other 978.838.7300
978.838.2786
266 River Road West Berlin, MA 01503-1699 USA
Tel: +1.978.838.7300
Other: 888.838.7300
Fax: 978.838.2786
©2025 Organomation
About Us
Policies