Pesticides are a significant source of environmental contamination that require careful monitoring and analysis to protect both human health and ecosystems. Organomation's specialized equipment plays a crucial role in the sample preparation process for pesticide analysis, enabling researchers and environmental professionals to achieve accurate, efficient, and reliable results.
Pesticides are widely used chemical products designed to control pests and prevent plant diseases, primarily in agriculture. However, their widespread application poses significant environmental and health concerns. A thorough understanding of the physical and chemical characteristics of pesticides is crucial for evaluating how they transform and behave in a given environment [1].
The adverse impacts of pesticide use are exemplified by imidacloprid, a common neonicotinoid insecticide. It has come under scrutiny due to its lethal effects on non-target species. Studies have shown that a significant amount of the imidacloprid applied to seeds remains in the environment rather than reaching intended targets. It can last for months to years in soil and then subsequently can reach surface waters through runoff and drainage. This has been shown to negatively impact invertebrate populations, including beneficial insects like honey bees [2].
The Environmental Protection Agency (EPA) has established several standardized methods for pesticide analysis in environmental samples:
EPA Method 1699 is specifically designed for analyzing various pesticides in water, soil, sediment, biosolids, and tissue samples using High-Resolution Gas Chromatography/High-Resolution Mass Spectrometry (HRGC/HRMS) [3]. This method explicitly recommends using nitrogen evaporation technology, such as Organomation's N-EVAP, to concentrate extracts before analysis.
EPA Methods 8081, 8082, and 8270 are essential for detecting hazardous organic pollutants in the environment, helping to protect public health, support regulatory compliance, and guide effective environmental management. These methods provide accurate data critical for informed decision-making and safeguarding ecosystems [4]. EPA Method 8081B is designed for analyzing organochlorine pesticides, while EPA Method 8082A targets polychlorinated biphenyls (PCBs). Both methods rely on meticulous sample preparation and use gas chromatography with electron capture detection (GC/ECD) to examine sample extracts [5, 6, 7]. EPA Method 8270, widely used for analyzing semi-volatile organic compounds (SVOCs) including many pesticides, employs gas chromatography-mass spectrometry (GC-MS) and offers enhanced sensitivity through selective ion monitoring (SIM). Accurate results depend on careful sample preparation, including extraction, concentration, cleanup, and, when needed, derivatization to improve compound detectability [4, 8].
Samples often require concentration prior to pesticide analysis, especially when detecting trace-level residues. More complex matrices such as soil, plant material, or biological tissues may also require additional preparation steps to reduce interferences and improve analyte recovery [3]. For example, solid samples like soil must be thoroughly homogenized to ensure representative results. The sample preparation process typically involves:
1. Sample collection and preservation
- Homogenization and drying of solid samples
2. Solvent extraction
- Liquid-liquid extraction (LLE), solid-phase extraction (SPE), solid-liquid extraction (SLE) [9]
3. Extract cleanup to remove interferences
- Typically seen more often with solid samples, specifically soil
4. Extract concentration using N-EVAP nitrogen evaporators
5. Instrumental analysis via GC-MS or LC-MS/MS
Pesticide analysis presents several unique challenges that make proper sample preparation essential:
- Complex Matrices: Pesticides must be extracted from diverse sample types, including water, soil, sediment, and biological tissues, and unknown matrix effects from these samples can impact analyte recovery and quantification [10].
- Low Concentration Levels: Environmental samples often contain pesticides at trace levels, such as parts per million (ppm) or parts per billion (ppb), requiring concentration steps to reach analytical detection limits.
- Sample Homogeneity: Sample types like soil can be heterogeneous in nature and require thorough mixing to ensure a representative sample distribution.
- Interference Removal: Environmental samples often contain interfering compounds that can co-extract with pesticides during sample preparation, complicating accurate detection and analysis.
- Analyte Specific Limitations: Different pesticides may require specific extraction and cleanup procedures, as their chemical properties may vary. Additionally, some pesticides may not be compatible with certain instrumental analysis methods, requiring alternative approaches for accurate detection [10].
Organomation offers specialized equipment designed to address the challenges of pesticide sample preparation, including:
The N-EVAP nitrogen evaporator series is specifically mentioned in EPA Method 1699 for concentrating pesticide extracts prior to analysis. These systems offer a wide range of benefits, including:
- Controlled evaporation with heated water baths and individual gas flow
- Multiple-sample processing capability for up to 45 vials
- Accurate and consistent temperature regulation
For larger volume reduction needs in pesticide analysis, Organomation has various options ranging in size. They offer these advantages:
- Higher throughput sample processing, up to 10 sample at once
- Reduced solvent usage and waste, with high solvent recovery up to 97%
- Compact, space-saving design with fewer water line connections
Extraction is a critical first step in pesticide analysis. Organomation’s extraction systems support the efficient isolation of soluble analytes from solid samples and enable continuous liquid-liquid extraction. Key benefits of Organomation’s extractors include:
- Efficiently separate pesticides from complex matrices
- Maintain sample integrity during the extraction process
- Improve recovery rates for target compounds
Investing in high-quality sample preparation equipment for pesticide analysis offers numerous benefits:
- Improved Detection Limits: Proper concentration techniques enable the detection of pesticides at environmentally relevant levels, accurately reflecting the concentrations found in natural settings.
- Enhanced Reproducibility: Standardized sample preparation leads to more consistent results across multiple samples and experiments.
- Reduced Interference: Effective cleanup procedures minimize the matrix effects that can compromise analytical results.
- Increased Laboratory Efficiency: Automated and semi-automated systems boost throughput, reduce labor costs, and enhance overall laboratory productivity.
Semi-volatile organic compounds (SVOCs) are environmental contaminants that pose significant danger to human health and the environment and are more likely to be found in liquid and solid forms. They commonly originate from pesticides and herbicides. Analysis of these samples relies heavily on proper sample preparation. Organomation’s S-EVAP concentrator can be used to streamline the process, improving sample throughput, solvent recovery, and overall reproducibility .
Researchers monitoring persistent organic pollutants (POPs) in environmental and biological samples rely on precise lipid extraction and concentration techniques. Common examples of POP’s include pesticides like DDT, aldrin, and chlordane. They are prone to accumulation and pose serious health and environmental risks, including cancer, reproductive disorders, and harm to wildlife. Detecting these compounds at trace levels is essential for protecting ecosystems and public health. Nitrogen evaporation plays a vital role in this process, particularly as a key step in EPA Method 1613. By enabling accurate and efficient sample concentration, nitrogen evaporators support critical efforts in environmental monitoring and contamination control.
EPA Methods 8081 and 8082 play a critical role in pesticide detection in soil at PDC Laboratories, where Organomation’s evaporators are essential to the sample preparation process. Method 8081 targets organochlorine pesticides, while Method 8082 focuses on polychlorinated biphenyls (PCBs), both of which require precise concentration of extracts prior to gas chromatography analysis. At PDC's Peoria location, soil samples are processed using the S-EVAP-KD for rapid concentration, followed by a solvent exchange and then a final concentration using the N-EVAP. This two-step evaporation workflow ensures accurate and efficient sample prep, with controlled concentration. Organomation’s durable and adaptable equipment continues to support PDC’s high-demand soil testing operations and uphold their reputation for excellence in environmental analysis [7].
Pesticide analysis requires meticulous sample preparation to ensure accurate, reliable results. By understanding the critical role of sample preparation in pesticide analysis and utilizing appropriate equipment, laboratories can enhance environmental monitoring, generate more reliable data for regulatory decisions, and ultimately support better protection of human health and ecosystems. Organomation's specialized equipment, including the N-EVAP nitrogen evaporators referenced in EPA Method 1699, provides environmental laboratories with the tools necessary to meet regulatory requirements and produce high-quality data for ongoing pesticide monitoring and research. With reliable instrumentation and a commitment to analytical precision, Organomation supports laboratories in advancing scientific analysis of pesticides.
Citations:
If you need support from one of our technicians, please fill out our Contact Help Support form and we will respond as quickly as possible! For all other enquiries, please use this general contact form.
USA 888.838.7300
Other 978.838.7300
978.838.2786
266 River Road West Berlin, MA 01503-1699 USA
Tel: +1.978.838.7300
Other: 888.838.7300
Fax: 978.838.2786
©2025 Organomation
About Us
Policies