Teflon-Free Nitrogen Evaporators for PFAS Analysis

Trusted by the Leading Environmental Labs

Designed specifically for PFAS sample preparation, our Teflon-free nitrogen evaporators help laboratories minimize the risk of fluoropolymer contamination during critical concentration steps. These systems are cited in EPA PFAS Methods 533, 537, 537.1, and 1633, supporting compliance with widely adopted regulatory workflows. Trusted by many of the industry’s largest environmental testing laboratories, they deliver reliable, contamination-free sample evaporation without compromising performance or throughput. 

#11155-NT ; #11250-NT

Teflon-Free N-EVAPs
for PFAS Research

DESCRIPTION

The Teflon-free N-EVAP nitrogen evaporators are designed for laboratories performing PFAS sample preparation and concentration. These evaporators allow multiple samples to be processed simultaneously while eliminating potential fluoropolymer contamination during nitrogen blowdown evaporation. Both the 12 and 24 position models are constructed using 100% Teflon-free components, ensuring that no PTFE or other fluoropolymers are present in the instrument.

Cited in EPA PFAS methods 533, 537.1, and 1633, these N-EVAP models are trusted by leading environmental research laboratories. 

The Teflon-free N-EVAPs are particularly suited for research laboratories, where workflows often involve multiple small batches, varying tube sizes, and shared instrumentation. Both models can accommodate 15 mL and 50 mL centrifuge tubes, providing flexibility for different PFAS preparation procedures. Each sample position includes an individual needle valve, allowing independent nitrogen flow control so samples with different evaporation endpoints can be processed at the same time.

For PFAS laboratories that require flexibility and contamination control, the Teflon-free N-EVAP provides an ideal solution. Laboratories processing large batches of identical samples may instead benefit from Organomation’s Teflon-free MULTIVAP nitrogen evaporators, which are designed for higher-throughput testing environments.

Learn how Waters Corporation uses a N-EVAP nitrogen evaporator to dry down their PFAS samples: Read case study!

Kari Organtini using N-EVAP  Kari Organtini, Principal Scientist at Waters Corporation

 

Small Footprint

N-EVAP Models 111 and 112 require about one square foot of bench space

Flexible

An adjustable sample holder design fits a wide variety of sample tubes and vials at once

Teflon-Free Guarantee

Made with 100% PTFE-free materials to avoid contamination of PFAS samples

Individualized Control

Optimize evaporation of diverse samples with individual gas flow control at each vial

STANDARD FEATURES

  • Nitrogen filter

  • Adjustable flow meter

  • Phthalate free silicon tubing eliminates contamination concerns

  • High temperature limit switch for safety

  • Dual band spring hoist assembly

  • Precision needle valve tube assembly

  • Needles, 4-inch x 19 gauge with chrome plated brass hub and stainless-steel shaft



OPTIONS (Add to main Cat# when purchasing) 

  • 220v wiring harness (Option Code# -2)
    • 12 position model: Cat# 11155-NT-2
    • 24 position model: Cat# 11250-NT-2
  • Reduced height (Option Code# -S)
    • 12 position model: Cat# 11155-NT-S
    • 24 position model: Cat# 11250-NT-S

 

 

 

SPECS

Instrumental Name Teflon-Free 12p N-EVAP Teflon-Free 24p N-EVAP
Bath Type Water Water
Instrumental Catalog Number 11155-NT 11250-NT
Number of Sample Positions 12 24
Standard Dimensions (w x d x h) 13 x 11 x 31 in
33 x 28 x 79 cm
16 x 15 x 33 in
41 x 38 x 61 cm
Reduced Height Dimensions (w x d x h) 13 x 11 x 24 in
33 x 28 x 61 cm
16 x 15 x 24 in
41 x 38 x 61 cm
Sample Holder Layout Circular Circular
Gas Manifold Layout Single Ring Single Ring
Test Tube Range (Standard) 10-30 mm OD 10-30mm OD
Test Tube Range (Optional) 5-16 mm OD 30-70 mm OD
Gas Flow Meter 0-10 L/min 0-20 L/min
Stainless Steel Needles (Length x Gauge) 4.0 in x 19 ga
102 mm x 19 ga
4.0 in x 19 ga
102 mm x 19 ga
Sample Tray Lift Mechanism Dual Band Spring Hoist Assembly Dual Band Spring Hoist Assembly
Standard Gas Input Range 20-30 psig 20-30 psig
Gas Input Range w/Optional Pressure Reducing Regulator 30-160 psig 30-160 psig
Heating Device Specs
Model Number
5585 9125
Heating Medium Water Water
Inside Dimensions (Diameter x Depth) 8.5 x 4.5 in
21.6 x 11.4 cm

12.0 x 4.5 in
30.5 x 11.4 cm

Outside Dimensions (w x d x h) 13 x 11 x 7 in
33 x 28 x 18 cm
16 x 15 x 7 in
41 x 38 x 18 cm
Total Wattage 550 W 900 W
Bath Temperature Range 30-90 °C 30-90°C
Temperature Controller Type
Mechanical Thermostat Mechanical Thermostat
Controller Accuracy +/- 2 °C  +/- 2 °C 

 

 

TESTIMONIALS

N-EVAP 11106 and 11634 testimonials

 

ACCESSORIES

  • Small vessel sample holder for 12 position N-EVAP model only, for vial outside diameters of 5-16 mm (cat# NA1132)

  • Large vessel sample holder for 24 position N-EVAP model only, for vial outside diameters of 30-56 mm (cat# NA1113)

  • Teflon-free nitrogen generator (cat# NA1955-NT)

  • Pasteur pipette adapters (cat# NA0636)

  • Teflon-free pressure reducing regulator 0-160 psi (cat# NA0630-NT)

  • Various needle sizes and gauges

REPLACEMENT PARTS

  • P0627: Valve Tube Assembly – Post 1997

  • P0607: Luer & washer for N-EVAP valve tube